WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller
Tehnilised andmed
- Toetatud seeriad: KEYENCE KV-8000, KEYENCE KV-X310
- Websait: http://www.keyence.com/
Paigaldusjuhend
HMI seadistus:
| Parameetrid | Soovitatav | Valikud | Märkmed |
| PLC tüüp | KEYENCE KV-8000/KV-X (Symbolic) (Ethernet) | ||
| PLC I/F | Ethernet | ||
| Sadam nr. | 8500 | ||
| Seadme tüüp | KV8000 | KV8000 / KVX | |
| On-line simulaator | Jah | Multi-HMI ühendus | Jah |
Ekspordi Tags:
Software KV STUDIO creates tag:
- Variable -> Cerected tag on Global or Local table.

- Support Sturcutre address.

- Ekspordi tag: File -> Output CSV/TXT file -> Variable information

Import Tags:
- In EasyBuilder Pro -> System Parameter Settings -> New Driver (KV-8000) -> Import Tags.

- Select the .txt file importida.

- Import some or all of the tags

- Valige tag you want to import in Tag Manager, press OK.

- Imporditud tag teave edukalt.

Tugiseadme tüüp
| Andmetüüp | EasyBuilderi andmevorming | Memo |
| BOOL | natuke | |
| INT | 16-bitine BCD, kuueteistkümnend, binaarne, allkirjastatud | 16-bitine |
| UINT | 16-bitine BCD, kuueteistkümnend, binaarne, allkirjastamata | 16-bitine |
| DINT | 32-bitine BCD, kuueteistkümnend, binaarne, allkirjastatud | 32-bitine |
| UDINT | 32-bitine BCD, kuueteistkümnend, binaarne, allkirjastamata | 32-bitine |
| PÄRIS | 32-bitine ujuk | 32-bitine |
| REAL | 64-bitine ujuk | 64-bitine *Märkus1 |
| STRING | Sõnade massiiv ASCII sisestamiseks ja kuvamiseks | *Märkus2 |
|
Massiiv |
BOOL, INT, UINT, DINT,UDINT, REAL,
LREAL, Structure *Märkus3 |
|
|
Struktuur |
BOOL, INT, UINT, DINT,UDINT, REAL, LREAL, STRING
Massiiv |
- Märkus1: EBPro V6.03.02 või uuem versioon toetab 64-bitist andmetüüpi (ainult cMT seeria), kuid pidage meeles, et aadressi piiranguvahemik on maksimaalselt 48 bitti.
- Märkus 2: String In EasyBuilder Pro, only even addresses can be selected, and support string length up to 2000.

- Märkus 3: Support 1~3D array, 4D arrays and above cannot be imported.
Ühendusskeem
Etherneti kaabel:

KKK-d
How do I connect multiple HMIs?
You can connect multiple HMIs using the on-line simulator option in the HMI settings.
What is the maximum string length supported for STRING data type?
In EasyBuilder Pro, only even addresses can be selected, and it supports string length up to 2000.
Dokumendid / Ressursid
![]() |
WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [pdfKasutusjuhend KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller |