LTECH-KBS-Switch-Module (6)

LTECH KBS Switch Module

LTECH-KBS-Switch-Module-PRODUCT

Süsteemi skeem

LTECH-KBS-Switch-Module (2)

Toote tutvustus

  • Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability.
  • Equipped with dual-relay functionality, enabling control of two sets of lighting devices.
  • Supports both mechanical and push switches. Even if the light is manually turned off, remote control via the APP remains available, meeting diverse needs.
  • Supports OTA (Over-the-Air) online upgrades, ensuring timely feature updates and usage safety, keeping the product up-to-date.
  • Supports direct connection to devices via smartphone, allowing direct control through the APP. Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more. Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
  • Compact size, allowing easy installation in European, American, and national standard junction boxes, suitable for various installation scenarios.
  • Supports power-off reset functionality and mechanical key reset functionality.

Tehnilised andmed

Mudel KBS
Traadita tüüp Bluetooth 5.2 SIG võrk
Vaheta kanalit 2 CH
Töömahttage 100-240V~, 50/60Hz,
Max. load current of the relay 10A
Max. load parameters of the relay Resistive load: 1000W@230Vac/CH, 500W@110Vac/CH, Max.2000W Capacitive load: 400W@230Vac/CH, 200W@110Vac/CH, Max.800W
Relee liigvool 70A@10ms
Töötemperatuur -25°C ~ 50°C
Toote suurus L45×L45.5×K20.5 (mm)
Toote kaal 30 g
Standardid UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、EN 62493:2015/A1:2022

Tootepildid

LTECH-KBS-Switch-Module (3)

Toote suurus

LTECH-KBS-Switch-Module (4)

Ühendusskeem

  1. Two mechanical switches control one relay each.
  2. One mechanical switch controls two relays.LTECH-KBS-Switch-Module (5)
  3. Two push switches control one relay each.
  4. One push switch controls two relays. LTECH-KBS-Switch-Module (6)

Soovitatavad rakendused

  1. Wireless light control
  2. After setting up the remote control association with the switch module via the APP, both the APP and the remote control can be used to control the device.LTECH-KBS-Switch-Module (7)
  3. Supports local scenes, gateway-free operation, and controllable even when offline.
  4. Work with intelligent gateway, it can realize visual control, cloud scene and automatic linkage. LTECH-KBS-Switch-Module (8)
  5. Intelligent control. Set up more app configs as you like

Rakenduse kasutusjuhised

  1. Registreeri konto
    Skannige allolev QR-kood oma mobiiltelefoniga ja järgige rakenduse installimise lõpuleviimiseks juhiseid. LTECH-KBS-Switch-Module (9)
  2. Parameetri seadistus
    More settings such as editable binding interface, group control, local scenes, cloud scenes, and automation. LTECH-KBS-Switch-Module (10)
  3. Binding interface settings
    After pairing is completed, enter the binding interface for the smart remote control/smart wireless switch. Select the switch module device to associate it, and then you can control the device’s on/off function using the smart remote control/smart wireless switch. You can also unbind the device from this interface. LTECH-KBS-Switch-Module (11)
  4. Light fixture group
    The same type of lighting fixtures can be grouped together, allowing users to control power on/off and other operations for the entire group, making operations more convenient. Switch to the “Group” menu, click the “+” icon in the upper right corner, follow the prompts to modify the group name, then click “Next,” select the devices you want to include in the group, and save. LTECH-KBS-Switch-Module (12)
  5. Kohalik stseen
    Switch to the 【Smart】 page, click “+” in the upper right corner to create a local scene, and after setting the execution action, you can realize the local linkage of Bluetooth devices. LTECH-KBS-Switch-Module (13)
  6. Pilvestseenid ja automatiseerimine
    Make sure that a smart gateway, such as SP-GW-6S,has been added to the family.
    Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved.
    Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkage LTECH-KBS-Switch-Module (14)

Lähtesta tehase vaikeseadetele

  • Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete.
  • Power Cycle Reset: With power off, switch device on for 15s then off. Repeat power on/off 6 times (2s on, 5s off each). On 7th power-on, connected fixture blinks 3 times, showing factory settings restored.
  • APP Reset: Click the ” ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset. LTECH-KBS-Switch-Module (1)

Tähelepanu

  • Product installation and commissioning should be done by a qualified professional. Our company products are and not lightning proof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices Good heat dissipation will prolong the working life of products. Please ensure good ventilation.
  • Palun kontrollige, kas töömahttage kasutatud vastab toodete parameetrinõuetele.
  • Kasutatava traadi läbimõõt peab olema võimeline koormama ühendatud valgusteid ja tagama kindla juhtmestiku.
  • Enne toodete sisselülitamist veenduge, et kõik juhtmestikud on õiged, kui vale ühendus võib kahjustada valgusteid.
  • Kui ilmneb rike, ärge proovige tooteid ise parandada. Kui teil on küsimusi, võtke ühendust oma tarnijatega.

Garantii leping

Garantiiperioodid alates tarnekuupäevast: 5 aastat.
Garantiiperioodide jooksul pakutakse tasuta remondi- või asendusteenust kvaliteediprobleemide korral.

Garantii välistused allpool:
Järgmised tingimused ei kuulu tasuta remondi- või asendusteenuste garantii alla:

  • Väljaspool garantiiaegu.
  • Mis tahes kunstlik kahjustus, mis on põhjustatud kõrge voltage, ülekoormus või ebaõiged toimingud. Raskete füüsiliste vigastustega tooted.
  • Loodusõnnetuste ja vääramatu jõu põhjustatud kahjud.
  • Garantiisildid ja vöötkoodid on kahjustatud.
  • Meie ettevõte pole ühtegi lepingut allkirjastanud.
  1. Klientidele on ainus võimalik õiguskaitsevahend toote parandamine või asendamine. Meie ettevõte ei vastuta juhuslike ega kaudsete kahjude eest, välja arvatud juhul, kui see on seadusega ette nähtud.
  2.  Meie ettevõttel on õigus käesoleva garantii tingimusi muuta või kohandada ning kirjalik vorm on ülimuslik.

Seda kasutusjuhendit võidakse ilma ette teatamata muuta. Toote funktsioonid sõltuvad kaubast. Küsimuste korral võtke julgesti ühendust meie ametlike edasimüüjatega.

Dokumendid / Ressursid

LTECH KBS Switch Module [pdfKasutusjuhend
KBS Switch Module, KBS, Switch Module, Module
LTECH KBS Switch Module [pdfKasutusjuhend
KBS, KBS Switch Module, Switch Module, Module
LTECH KBS Switch Module [pdfKasutusjuhend
2AYCY-KBS, KBS Switch Module, KBS, Switch Module, Module

Viited

Jäta kommentaar

Teie e-posti aadressi ei avaldata. Kohustuslikud väljad on märgitud *