Tehnilised andmed

  • Toiteallikas: 200 – 240VAC 50-60Hz
  • Kontakti reiting: 230 Vac 10(3)A
  • Ümbritsev temperatuur: 0…45˚C
  • Automaatne toiming: Type 1. C.
  • Seadmete klassid: II klassi seadeEPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-1
  • Reostusaste: Reostusaste 2
  • IP reiting: IP20
  • Rated Impulse Voltage: Vastupidavus voltage liigpinge 2500 V vastavalt standardile EN 60730

Kuidas teie TR1 TR2V2 töötab

  • Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
  • The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
  • When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
  • It is possible to send a wireless signal in one direction or both.
  • When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
  • When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
  • Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
  • It is possible to have more than one set of TR1, TR2V, 2and, where required.
  • Please see pages 9-13 for wiring examples

TR1TR2V2 sisemine ühendusskeem

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-2ETTEVAATUST. Installation should only be carried out by a qualified person and by wiring regulations.

Switching  Options

Toitevõrgu lülitamine

  • Link L to 3

Madal kdtage Lülitamine

  • Remove the external controls link from the boiler PCB.
  • Connect 2 and 3 to these terminals.

Paigaldamine ja paigaldamine

  1. The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
    1. Single-gang recessed back box.
    2. Pindkinnituskarbid
    3. Directly mounted on a wall.
  2. Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
  3. Screw the backplate to the wall with the screws provided.
  4. Ühendage tagaplaat vastavalt juhtmestikule.
  5. Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-3EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-4

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-5

Nupp / LED Kirjeldus

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-6

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7Käsiraamat Press to activate or deactivate the Live out terminal.
EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8Ühendage Hold for 3 seconds to initialise the pairing process. The RF light will flash.
EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-9Lähtesta Press to reset the T, R1, TR2V2.
Märkus. The connection procedure is not required as both TR1 & TR2V2 are pre-paired

LED Kirjeldus

LED Värv Kirjeldus
Otse LED-is Punane Ei ole voltage on the Live terminal.
Roheline Seal on voltage faasisisendklemmil – Nüüd saadetakse teisele RF-pealülitile raadiosagedussignaal, et aktiveerida faasiväljundklemm.
RF LED Valge Põlev valge LED-tuli, mis näitab, et termostaat on ühendatud.
RF-tuli vilgub kaks korda, kui termostaat on lahti ühendatud. Kontrollige termostaadi sidumist.
             Märkus. RF-tuli vilgub vahelduvalt, kui süsteem saadab ja võtab vastu sidesignaali.
            Märkus. The RF light will blink once every second when in RF pairing by holding Connect. Press the Manual to exit from this state.
Otseülekande LED Punane Teiselt raadiosagedusliku pealülitilt pole raadiosageduslikku aktiveerimissignaali vastu võetud.
Roheline RF activation signal has been received from the other RF Mains Switch.

To connect the TRI TR2V2
Pange tähele: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.

On TR1V2:

  • Hoia EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.

On TR2V2:

  • Hoia EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-83 sekundiks.
  • The RF LED will begin to flash, and the Live out LED will appear solid green.
  • When connected, all three LEDs will appear solid.

On TR1V2:

  • Vajutage nuppu EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7to exit the pairing mode.
  • After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.

To disconnect the TRI TR2V2

  • Hoia EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.
  • Hoia EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 10 seconds until the Live in LED appears solid red.

On TR2V2:

  • Hoia EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.
  • Hoia EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8Connect for 10 seconds until the Live in & Live out LED appears solid red.

On TRIV2:

  • Vajutage EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7väljumiseks.
  • The TRI TR2V2 is now disconnected.

Juhtmestik Examples

Example  One way RF Switch: Programmer to Boiler – Mains Switching

TR1V2 
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.

TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-11

Paigaldamise märkused

  1. Mains Switching Boiler
  2. Madal köidetage Switching Boiler
  • TR2V2 peal
  • On the boiler PCB
  • TR2V2 peal
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.

Example 2 Two Two-way RF Switch:

  1. Programmer to Motorised Valve
  2. Motorised Valve to Boiler – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out contact closes, sending 230V to activate the boiler.

TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-12

Paigaldamise märkused

1. Main Switching Boiler
2. Väikese mahugatage Switching Boiler
3. Mootorventiil

  • On the TRIV2
  • On the boiler PCB
  • On the TRIV2
  • TR2V2 peal
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the motorised valve.

Example 3 One way RF Switch:
Pump Overrun – Mains Switching

TR 1 v2

  • On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.

TR2V2

On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-13

Paigaldusmärkus

  • Pump Sees
  • the TR2V2
  • Link L to 3 to power the Live out terminal to the pump

Example 4 Two Two-way RF Switch: Pump Overrun

  1. Programmeerija katlale
  2. Boiler to Pump – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out contact closes, sending 230V to activate the pump.

TR2V2

  • On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-14Paigaldusmärkus

  1. Mains Switching Boiler
  2. Madal köidetage Switching Boiler
  3. Pump
  • TR2V2 peal
  • On the boiler PCB –
  • TR2V2 peal
  • On the TRIV2
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the pump.

Example 5 Two Two-way RF Switch: Unvented Cylinder:

  1. Programmeerija ülempiiri termostaadile
  2. Motorised Valve to Boiler – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out the contact closes, sending 230V to activate the boiler.

TR2V2

On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-15Paigaldamise märkused

  1. Mains Switching Boiler
  2. Madal köidetage Switching Boiler
  3. Kõrge piiriga termostaat
  4. Mootoriga ventiil
  • On the TRIV2
  • On the boiler PCB
  • TR2V2 peal
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the High Limit thermostat.

EPH juhib IE-d
Technical@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-16

EPH kontrollib Ühendkuningriiki
Technical@ephcontrols.co.uk
www.ephcontrols.co.uk/
võtke meiega ühendust
+44 1933 322 072
Harrow, HAI IBDEPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-17

KKK-d

Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.

Q: What is the maximum distance between TR1V2 and TR2V2 for effective communication?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.