  • Kohandatud protokolli loomise juhend
  • Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
  • Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2

Toote kasutusjuhised

Sissejuhatus:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Nõuded seadistamisele:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

ÜHILDUV PÜSIVARA

Kohandatud protokolli loomine on saadaval järgmistes ENTTEC pikslikontrollerites:

SKU Toode Püsivara versioon
73539 DIN PIXIE V2.0 või uuem
70067 PIXELATOR MINI V2.0 või uuem
70068 PIXELATOR MINI MK2 V1.0 või uuem
71521 OKTO MK2 V4.0 või uuem
71522 OKTO MK3 V1.0 või uuem

SISSEJUHATUS

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • See funktsioon võimaldab kasutajatel volüümi reguleeridatage ajastus, mis põhineb toetatud protokollidel, kui andmeedastusmeetod ühtib mõne meie toetatud protokolliga.
  • See dokument sisaldab häälestusjuhiseid kohandatud piksliprotokolli loomiseks ja kriteeriumide kontrollimiseks.

SEADISTUSNÕUDED

Kohandatud protokolli loomiseks on vaja järgmist.

  1. Andmeleht: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Seade: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

KOHALDATUD PROTOKOLLIDE LOOMISE JUHEND

See funktsioon võimaldab kasutajatel kohandada andmemahtutage timing to meet specific protocol needs. To create a custom protocol:

  1. Kontrollige ühilduva piksliprotokolli andmelehte.
  2. Kohandatud protokolli funktsiooni lubamiseks liikuge seadme kasutajaliidesele.
  3. Reguleerige piksliseadme andmemahtutage ajastus kaudu web liides vastavalt tootja andmelehele.

1. samm: kontrollige ühilduva protokolli andmelehte

  1. Kontrollige andmelehel soovitud protokolli andmeedastusmeetodit.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Kõige tavalisem meetod edastab andmeid ilma täiendavate bittideta (nt D1-D2-D3…Dn).
        Example: teave on võetud WB2812B andmelehelt

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Mõned protokollid, nagu TM1814, sisaldavad lisaandmeid ees (nt C1-C2-D1-D2…Dn).
        Example: teave on võetud TM1814 andmelehelt

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Määrake seadme poolt toetatav sobitusprotokoll (või valige ülaltoodud ntample) that shares the same data transmission method as your desired pixel protocol.
  3. Edasiseks konfigureerimiseks jätkake 2. sammuga.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web liides
    1. Google Chrome'i soovitatakse web browser to access the OCTO/PIXELATOR MINI’s web liides.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC websaidil www.enttec.com rakenduse allalaadimiseks.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Minge väljundisse, kuhu soovitud piksliseade on ühendatud. Valige ripploendist piksliprotokoll, mis jagab 1. sammus kinnitatud edastusmeetodit.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Andmemahule juurdepääsuks lubage märkeruut „Kohandatud”.tage ajastuse seadistus. Kohandatud protokolli keelamiseks tühjendage linnuke.

    ENTTEC-73539-DIN-PIXIE-FIG-6

DIN PIXIE jaoks

  1. Ühendage DIN PIXIE arvutiga USB Type-B abil.
  2. Käivitage EMU tarkvara.
  3. Otsige seadet ja klõpsake avastatud DIN PIXIE nuppu Conf.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

3. toiming: seadistage kohandatud voltage ajastus

  1. Sobitage voltage ajastus soovitud protokolli andmelehel. Kohandatud protokoll nõuab andmete mahu täitmiseks 4 sisendittage ajastuse reguleerimine:
    Voltage Timing Definition
    Biti 0 kõrgaeg (T0H) VoltagKoodi 0 jaoks kuluv kõrge aeg.
    Biti 1 kõrgaeg (T1H) VoltagKoodi 1 jaoks kuluv kõrge aeg.
    Overall Bit Time: Kogumahttage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Lähtesta aeg Kogumahttagiga andmepartii vahelise andmeedastuse lähtestamiseks kuluv aeg.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Andmeleht – Data voltage ajastuse teave Ntample
    WB2818B andmelehelt
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage ajavahemik.
    • Täida voltage ajavahemik väljundi sätete kohandatud väljal.

      ENTTEC-73539-DIN-PIXIE-FIG-10

TÄHTIS

  • ENTTEC recommends taking the median value of the range for the start.
  • Muudetud väärtuse jõustumiseks peab kasutaja sätted SALVESTAMA.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

KOKKUVÕTE

  • See juhend näitas, kuidas seadistada kohandatud protokolli sobilike ENTTEC-seadmete jaoks, ja andis tehnilisi teadmisi soovitud piksliseadmete andmelehe kontrollimiseks.
  • Neid samme järgides saavad kasutajad luua kohandatud piksliprotokolli, mida ripploendist ei leidu, ootamata tehnilist tuge või uut püsivara väljalaset. Kui teil on küsimusi või raskusi õige teabe leidmisega, võtke ühendust meie sõbraliku tugimeeskonnaga kohalikes kontorites.

KKK

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web brauser.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.