1. Sissejuhatus
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.
2. Ohutusalane teave
Toote kahjustamise vältimiseks ja kasutaja ohutuse tagamiseks järgige järgmisi ohutusnõudeid:
- Toiteallikas: Use only the specified power supply for this device. Ensure the power source meets the voltage ja kehtivad nõuded.
- Keskkond: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
- Ventilatsioon: Tagage seadme ümber piisav ventilatsioon, et vältida ülekuumenemist. Ärge blokeerige ventilatsiooniavasid.
- Paigaldamine: Paigaldus peaks toimuma kvalifitseeritud personali poolt vastavalt kohalikele elektrieeskirjadele ja -määrustele.
- Hooldus: Ärge proovige seadet ise avada ega hooldada. Jätke kogu hooldus kvalifitseeritud hooldustöötajatele.
- kaablid: Use appropriate and certified cables for all connections.
3. Pakendi sisu
Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.
- AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
- Kiirpaigaldusjuhend
- Mounting Kit (e.g., DIN rail clip, screws)
- Terminal Block Connectors (for power input)
4. Toote lõppview
The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.
4.1 Esipaneeli paigutus

Joonis 1: Esiosa view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

Joonis 2: Detailne esikülg view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.
4.2 Components Description
- Etherneti pordid (1–4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- Etherneti pordid (5–8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- 10G pordid (9–10): 10 Gigabit SFP+ uplink ports for high-speed connections.
- Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
- Konsooli port: RJ45 port for local management and configuration via a serial connection.
- Lähtestamisnupp: Used to reset the device to factory defaults or reboot.
- LED indikaatorid:
- SYS: Süsteemi oleku indikaator.
- P1, P2: Power input status indicators.
- ALM: Häire indikaator.
- RM, RC: Redundancy Management / Redundancy Control indicators.
5. Seadistamine
5.1 Paigaldamine
The AXIS D8208-R is designed for DIN rail mounting.
- Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
- Hook the top edge of the DIN rail clip onto the DIN rail.
- Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
- Ensure the switch is securely fastened to the DIN rail.
5.2 Toiteühendus
The switch supports redundant power inputs (P1 and P2) for increased reliability.
- Ensure the power source is turned off before making any connections.
- Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
- Insert the terminal block connector into the P1 power input port on the switch.
- (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
- Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.
5.3 Võrguühendus
Connect network devices and uplink connections.
- Standardseadmed: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
- Üleslink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.
5.4 Esialgne konfiguratsioon
Lülitit saab konfigureerida a kaudu web-based interface or a command-line interface (CLI) through the console port.
- Web Liides: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
- Konsooli port: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.
6. Töötamine
6.1 LED indikaatorit
Monitor the LED indicators for the operational status of the switch.
| LED | Olek | Kirjeldus |
|---|---|---|
| SYS | Roheline (tahke) | Süsteem töötab normaalselt. |
| SYS | Roheline (vilkuv) | System is booting or performing an operation. |
| P1 / P2 | Roheline (tahke) | Corresponding power input is active. |
| ALM | Red (Solid/Flashing) | An alarm condition exists (e.g., power failure, port error). Check system logs. |
| Sadama valgusdioodid | Roheline (tahke) | Link loodud. |
| Sadama valgusdioodid | Roheline (vilkuv) | Andmetegevus. |
6.2 Haldamine ja konfigureerimine
The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.
- Web-põhine GUI: Juurdepääs lülitile web liides standardi kaudu web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
- CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
- SNMP: Kommutaator toetab SNMP-d võrguhaldussüsteemidega integreerimiseks.
7. Hooldus
7.1 Puhastamine
To maintain optimal performance, periodically clean the exterior of the switch.
- Enne puhastamist veenduge, et toide on lahti ühendatud.
- Välispindade pühkimiseks kasutage pehmet ja kuiva lappi.
- Ärge kasutage vedelaid ega aerosoolpuhastusvahendeid, kuna need võivad seadet kahjustada.
- Hoidke ventilatsiooniavad tolmust ja prahist vabad.
7.2 Püsivara värskendused
Regularly check the Axis Communications website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements.
- Laadige alla sobiv püsivara file from the official Axis Communications support page for your model.
- Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web liides.
8. Veaotsing
If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.
- Toide puudub:
- Check power cable connections to the switch and the power source.
- Veenduge, et toiteallikas töötab korralikult ja annab õiget helitugevusttage.
- Ensure the P1/P2 LEDs are illuminated.
- Võrguühendus puudub:
- Check Ethernet cable connections for both the switch and the connected device.
- Verify the link/activity LEDs on the respective port are active.
- Veenduge, et ühendatud seade on sisse lülitatud ja õigesti konfigureeritud.
- Check switch configuration (VLANs, port status) via the web liides või CLI.
- PoE-seade ei lülitu sisse:
- Ensure the connected device is PoE compatible and within the switch's PoE budget.
- Check the PoE status for the port in the switch's management interface.
- Verify the Ethernet cable is a standard Cat5e/6 or higher.
- Juurdepääs Web Interface Fails:
- Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
- Try accessing the switch via the console port to verify its IP configuration.
- Tühjendage oma brauseri vahemälu või proovige mõnda teist brauserit.
- Tehaseseadete taastamine: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Hoiatus: See kustutab kõik kohandatud konfiguratsioonid.
9. Tehnilised andmed
| Funktsioon | Detail |
|---|---|
| Kaubamärk | Axis Communications |
| Mudeli number | 02621-001 |
| Toote nimi | AXIS D8208-R Industrial 8-Port Managed PoE++ Switch |
| Sadamad | 8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+ |
| Toite sisend | Redundant DC power input (terminal blocks) |
| Kauba kaal | 3.37 naela (umbes 1.53 kg) |
| Pakendi mõõtmed | 1.97 x 0.79 x 0.79 tolli (umbes 5 x 2 x 2 cm) |
| Tootja | AXIS - ACCESS CONTROL |
| Esmakordselt saadaval olev kuupäev | 29. mai 2024 |
10. Garantii ja tugi
For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications websaidile.
Websait: www.axis.com
Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.