The Vantec EEI 25-40/180 High-Efficiency Circulation Pump is designed to facilitate forced circulation within central heating systems. Equipped with an inverter and a processor, the pump automatically adjusts its power and pressure parameters to meet the specific demands of the system. This design ensures efficient and stable operation with minimal energy consumption.

Key operational characteristics include quiet performance, very low energy consumption (as low as 5 W), and resistance to corrosion, contributing to its durability and reliability in various heating and cooling applications.

2. Ohutusalane teave

Before installation, operation, or maintenance, carefully read and understand all instructions in this manual. Failure to follow these instructions may result in property damage, injury, or death. Ensure all electrical connections are performed by a qualified electrician in accordance with local regulations. Always disconnect power before performing any service or maintenance on the pump. Do not operate the pump if it is damaged or if any electrical components are exposed to moisture.

3. Pakendi sisu

Pärast lahtipakkimist veenduge, et kõik komponendid on olemas ja kahjustamata:

Vantec EEI 25-40/180 pump and accessories in packaging

Image: The Vantec EEI 25-40/180 circulation pump shown with its included accessories, such as the power cable, screw fittings, and gaskets, all within its product packaging.

4. Seadistamine ja installimine

Installation of the Vantec EEI 25-40/180 pump should be carried out by qualified personnel to ensure proper function and safety. The pump is designed for integration into existing or new central heating systems.

4.1. Mehaaniline paigaldus

  1. Ensure the system is depressurized and drained before installation.
  2. Mount the pump in the designated location, ensuring the flow direction matches the system. The pump has a spacing of 180 mm between connections.
  3. Use the provided screw fitting kit and gaskets to connect the pump to the system piping. The connection diameter is 1 1/2" - 1". Tighten connections securely to prevent leaks.
Vantec EEI 25-40/180 pump with screw fittings attached

Image: The Vantec EEI 25-40/180 pump with its screw fittings installed, illustrating how it connects to system piping.

Included screw fitting kit and gaskets

Pilt: detailne view of the screw fitting kit and gaskets provided for secure and leak-proof installation.

4.2. Elektriühendus

  1. Connect the provided power cable to the pump's electrical input.
  2. Plug the power cable into a suitable 230 V/50 Hz electrical outlet. Ensure the power supply is stable and meets the pump's requirements.
Power cable with plug for Vantec pump

Image: The power cable with a standard plug, used to connect the pump to the main electrical supply.

5. Kasutusjuhised

The Vantec EEI 25-40/180 pump features an electronic control panel for easy operation and monitoring.

5.1. Initial Start-up and Auto-Adaptive Function

The pump is equipped with an auto-adaptive function, allowing it to start without requiring manual adjustments. It automatically and continuously adjusts its power to the system's needs through a permanent magnet motor and differential pressure regulator.

5.2. Electronic Control Panel

The electronic control panel is located on the top of the motor. Its digital display shows the current energy consumption in watts (W) or meters (m) of head. Use the control buttons to navigate through settings or modes if available (specific button functions are typically detailed in a separate quick start guide or on the device itself).

Close-up of Vantec EEI 25-40/180 pump control panel

Pilt: Lähivõte view of the electronic control panel, highlighting the digital display and control buttons for monitoring and adjusting pump operation.

5.3. Applicable Systems

This circulation pump is suitable for a variety of applications, including:

6. Hooldus

The Vantec EEI 25-40/180 pump is designed for minimal maintenance due to its robust construction and corrosion-resistant materials. Regular checks can help ensure optimal performance and longevity.

For any internal maintenance or repairs, it is recommended to contact a qualified service technician.

7. Veaotsing

If the pump is not operating as expected, consider the following basic checks:

For complex issues or if basic troubleshooting does not resolve the problem, contact a qualified service technician or the manufacturer's support for assistance.

8. Tehnilised andmed

FunktsioonSpetsifikatsioon
Rated Voltage230V/50Hz
Energiatarve5–22 W
Maksimaalne voolukiirus48 l/min
Max pea4.5 m
Max töörõhk10 baari
Töötemperatuur+2 °C kuni +110 °C
Spacing (Port-to-Port)180 mm
Ühenduse läbimõõt1 1/2" - 1"
Kaitse indeksIP44
Mõõdud (P x L x K)23 x 20 x 13 cm
Kaal2.35 kg
Mootori mähis100% vask

9. Garantii ja tugi

The Vantec EEI 25-40/180 Circulation Pump is covered by a manufacturer's warranty. Please refer to the warranty documentation provided with your purchase for specific terms and conditions. For technical support, service, or warranty claims, please contact your retailer or the Vantec customer service department. Keep your proof of purchase for warranty validation.

Seotud dokumendid - EEI 25-40/180

Preview Vantec NST-M240C4 M.2 NVMe korpuse paigaldusjuhend
Samm-sammult paigaldusjuhend Vantec NST-M240C4 M.2 NVMe korpuse jaoks. Siit saate teada, kuidas paigaldada oma NVMe SSD-d, seda kasutamiseks ette valmistada ja staatilise elektri suhtes tundlikke seadmeid käsitseda.
Preview Vantec UGT-S100 7.1-kanalilise PCI-helikaardi kasutusjuhend
Vantec UGT-S100 7.1-kanalilise PCI-helikaardi kasutusjuhend, mis kirjeldab funktsioone, süsteeminõudeid, paigaldusjuhiseid, füüsilisi ühendusi ja garantiiteavet.
Preview Vantec ALL in 1 multifunktsionaalne sisemine kaardilugeja UGT-CR955-BK kasutusjuhend
User manual for the Vantec ALL in 1 Multifunction Internal Card Reader (Model: UGT-CR955-BK). Features include support for 59 memory card types, eSATA, USB 2.0, and FireWire ports. Installation, specifications, FAQ, and contact information.
Preview Vantec USB 3.0 universaalne mini dokkimisjaama adapter DSH-M100U3 kasutusjuhend
Vantec DSH-M100U3 USB 3.0 universaalse mini-dokkimisjaama adapteri kasutusjuhend. Siit leiate teavet selle funktsioonide, süsteeminõuete, installimise ja ekraanikonfiguratsiooni kohta Windowsi ja Mac OS X-i jaoks.
Preview Vantec NexStar DX2 välise optilise draivi korpuse KKK - NST-540S3-BK
Korduma kippuvad küsimused (KKK) Vantec NexStar DX2 välise optilise draivi korpuse (mudel NST-540S3-BK) kohta. Hankige vastuseid oma SATA optilise draivi paigaldamise, ühenduvuse, toite, ühilduvuse ja tõrkeotsingu kohta.
Preview Vantec CB-ISA225-U3 SATA/IDE USB 3.0 adapteri kasutusjuhend
Põhjalik juhend Vantec CB-ISA225-U3 adapteri kohta, mis kirjeldab üksikasjalikult selle võimalusi, vastab korduma kippuvatele küsimustele ja annab samm-sammult juhiseid SATA ja IDE kõvaketaste ühendamiseks.