This manual provides essential information for the safe and efficient operation of your EPEVER 3000W Pure Sine Wave Inverter. This inverter converts 24V DC power to 110V AC power, suitable for various off-grid applications. It features a double closed-loop control algorithm for fast response and load impact resistance, ensuring stable and reliable power output.

Põhifunktsioonide hulka kuuluvad:

  • 3000W continuous power output, 6000W surge power for 5 seconds.
  • Ühildub 24V liitium- ja pliiakudega.
  • Rotatable LCD meter for monitoring and parameter configuration.
  • Remote control capability via phone apps and PC software.
  • Built-in electronic safeguards for comprehensive protection.
EPEVER 3000W Pure Sine Wave Inverter overview
Joonis 1: Üleview of the EPEVER 3000W Pure Sine Wave Inverter, highlighting its compatibility with 24V lithium and lead-acid batteries, 6000W surge power, remote control, and compliance with IEC62109, EN61000, RoHS standards.

2. Ohutusjuhised

Read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Veenduge, et muundur on korralikult maandatud.
  • Ärge jätke inverterit vihma, lume, pritsmete ega liigse tolmu kätte.
  • Install the inverter in a well-ventilated area to prevent overheating.
  • Ärge avage inverterit casing; sees ei ole kasutaja poolt hooldatavaid osi.
  • Enne mis tahes juhtmestiku või hooldustööde tegemist ühendage kõik toiteallikad lahti.
  • Kasutage kõigi ühenduste jaoks sobivaid juhtmediameetriid, et vältida ülekuumenemist ja tagada tõhus energiaülekanne.
  • Hoidke lapsed inverterist ja selle ühendustest eemal.
Built-in electronic safeguards of the EPEVER inverter
Figure 2: The inverter includes built-in electronic safeguards such as input reverse polarity protection, inverter over temperature protection, over voltage protection, input voltage protection, overload protection, and output short circuit protection to prevent damage from installation errors or system failures.

3. Toote komponendid

Familiarize yourself with the various parts of your EPEVER inverter:

EPEVER Inverter component diagram
Figure 3: Detailed diagram of the inverter's components. 1. DC input terminal positive, 2. DC input terminal negative, 3. Cooling fan, 4. LCD, 5. AC outlet, 6. RS485 communication port, 7. USB output port 5VDC/Max.1A, 8. External switch port, 9. Inverter switch, 10. Grounding terminal.

4. Seadistamine ja installimine

Follow these steps for proper installation of your inverter:

4.1 Paigaldamine

  • Valige kuiv, hästi ventileeritav koht, eemal otsesest päikesevalgusest ja soojusallikatest.
  • Ensure adequate clearance around the inverter for airflow (minimum 150mm on all sides for air intake and outlet).
  • Mount the inverter securely to a stable surface using appropriate fasteners.

4.2 Juhtmete ühendamine

The inverter features a push-on terminal design for easy wire installation without a screwdriver for the AC output. For DC input, use the screw terminals.

EPEVER Inverter wiring installation with push-on terminals
Figure 4: Wiring installation demonstrating the push-on terminal design for AC output. For multi-stranded wires, add solder to the connection point before inserting into the corresponding port. To remove, stop the inverter, insert a sharp tool into the small hole, and pull out the wiring.
  1. Maandus: Connect the grounding terminal (10) to an earth ground.
  2. DC sisend: Connect the positive (1) and negative (2) DC input terminals to your 24V battery bank. Ensure correct polarity.
  3. AC väljund: Connect your AC loads to the AC outlet (5). The push-on terminals simplify this connection.
  4. Valikulised ühendused: Connect the RS485 communication port (6) or USB output port (7) for remote monitoring or charging devices.

4.3 Aku ühilduvus

The inverter is compatible with both 24V lithium and lead-acid batteries (AGM/GEL/LFP).

EPEVER Inverter battery compatibility
Figure 5: The inverter is compatible with 24V lithium and lead-acid battery types, including AGM, GEL, and LFP. It incorporates surge current suppression technology to protect lithium batteries.

5. Kasutusjuhised

5.1 Sisse-/väljalülitamine

  • To power on, ensure all connections are secure, then press the inverter switch (9). The LCD will illuminate.
  • To power off, press the inverter switch (9) again.

5.2 LCD-ekraan ja juhtnupud

The rotatable LCD meter (4) provides real-time status and allows parameter configuration.

EPEVER Inverter LCD display and controls
Figure 6: The LCD display (1) can be rotated 180 degrees for convenience. It features UP/Setting button (2), Fault indicator (red) (3), Working status indicator (Blue) (4), and DOWN/Enter button / Output ON/OFF button (5). The blue working status indicator shows solid for normal operation, slow flashing (1/4Hz) for standby, fast flashing (1Hz) for fault, and off when powered down.

5.3 Kaugseire

The inverter supports remote control and monitoring via phone applications and PC software using the RS485 communication port (6) or an optional eBox-WIFI-01 module.

EPEVER Inverter remote control setup
Figure 7: The inverter can be remotely controlled and monitored via smartphone apps (available on App Store and Google Play) or PC software, typically requiring an eBox-WIFI-01 module connected to the RS485 port.

5.4 Load Compatibility

The inverter is suitable for a wide range of daily appliances. Ensure the total wattage of connected appliances does not exceed the inverter's rated power.

EPEVER Inverter load compatibility examples
Joonis 8: näitamples of compatible appliances include washing machines, TVs, refrigerators, drills, air conditioners, water pumps, laptops, and kettles. Always avoid overloading the inverter. Different types of loads have varying starting impulse currents; select an inverter model appropriate for your equipment's power, current, and load characteristics.

6. Hooldus

Regulaarne hooldus tagab teie inverteri optimaalse jõudluse ja pikaealisuse.

  • Puhastamine: Puhastage inverteri välispinda regulaarselt kuiva lapiga. Veenduge, et ventilatsiooniavad oleksid tolmust ja prahist vabad.
  • Ühendused: Check all electrical connections regularly to ensure they are tight and free from corrosion.
  • Keskkond: Maintain a suitable operating environment, avoiding extreme temperatures and humidity.

7. Veaotsing

Kui teil tekib inverteriga probleeme, vaadake järgmisi levinud probleeme ja lahendusi:

ProbleemVõimalik põhjusLahendus
Inverter ei lülitu sisseNo DC input power; Loose battery connections; Low battery voltageKontrollige aku ühendusi ja voltage; Ensure battery is charged; Verify inverter switch is ON.
Vahelduvvoolu väljund puudubOverload; Short circuit; Over-temperature; Inverter faultReduce load; Check for short circuits in AC wiring; Allow inverter to cool; Check fault indicator on LCD.
Fault indicator (red) is onInternal fault; Input/output protection triggeredRefer to the LCD display for specific error codes if available; Disconnect loads and restart inverter; If fault persists, contact support.
Madal väljundvõimsusAku tühjeneminetage; Excessive load; Poor DC connectionsCharge battery; Reduce load; Tighten DC connections.

8. Tehnilised andmed

SpetsifikatsioonVäärtus
KaubamärkIGAGI
Mudeli nimi3000W
Hinnatud sisend Voltage24VDC
Väljund Voltage110VAC (±3%); 120VAC (-7%~+3%)
Väljundsagedus50/60 Hz ±0.2%
Pidev väljundvõimsus3000 vatti
Peak Output Power (Surge)6000 vatti (5 sekundit)
Electrical Output WaveformPuhas sinine laine
USB väljund5VDC/Max.1A
RS485 sideport5VDC / 200mA
Ühilduvad akutüübid24V Lithium and Lead-acid battery
Turustusvõimaluste arv1
Energy Specifications MetIEC62109, EN61000, RoHS
Kauba kaal23.2 naela

9. Garantii teave

This EPEVER inverter comes with a 1-aastane garantii from the date of purchase. The warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications. Please retain your proof of purchase for warranty claims.

10. Klienditugi

For technical assistance, troubleshooting, or warranty inquiries, please contact EPEVER customer support through their official website or the contact information provided with your purchase. When contacting support, please have your product model number (3000W) and purchase details ready.

Seotud dokumendid - 3000W

Preview EPEVER IPOWER seeria puhta siinuslaine inverteri kasutusjuhend
See dokument annab EPEVER IPOWER seeria puhta siinuslaine inverterite põhjalikud kasutusjuhised. See hõlmab olulisi ohutusnõudeid ja üleview of the product, model designations, wiring diagrams, functional descriptions, protection mechanisms, troubleshooting guidance, maintenance procedures, a disclaimer, and detailed technical specifications for various models.
Preview EPEVER Pure Sine Wave Inverter User Manual
User manual for EPEVER Pure Sine Wave Inverters (IPower series), detailing safety instructions, functions, specifications, wiring, and troubleshooting for models like IP350, IP500, IP1000, IP1500, and IP2000.
Preview EPEVER IPT seeria puhta siinuslaine inverteri kasutusjuhend
Discover the EPEVER IPT Series Pure Sine Wave Inverter User Manual. This guide covers safety, installation, operation, and specifications for models IPT350 to IPT5000, ensuring reliable power for solar, RV, and home systems.
Preview EPEVER IPower seeria puhta siinuslaine inverteri kasutusjuhend
This user manual provides comprehensive guidance for EPEVER IPower series pure sine wave inverters, covering safety instructions, product introduction, model details, wiring procedures, operational functions, protection features, troubleshooting steps, maintenance guidelines, legal disclaimers, and detailed technical specifications.
Preview EPEVER IPT Series Pure Sine Wave Inverter User Manual | Installation & Operation Guide
Comprehensive user manual for EPEVER IPT series pure sine wave inverters. Covers safety, installation, operation, parameter settings, troubleshooting, and technical specifications for reliable DC-AC off-grid power solutions.
Preview EPEVER IPT seeria puhta siinuslaine inverteri kasutusjuhend
Põhjalik kasutusjuhend EPEVER IPT seeria puhta siinuslaine inverterite kohta, mis hõlmab ohutusjuhiseid, paigaldus-, kasutus-, hooldus-, tõrkeotsingu- ja tehnilisi kirjeldusi mudelitele IPT350 kuni IPT5000.