1. Sissejuhatus
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Smith's Environmental Products Quiet-One Kickspace Fan Heater, Model B628330. This unit is designed to provide supplemental heat by circulating hot water from your central heating system through a heat exchanger and distributing the warmth with an integrated fan. Please read all instructions carefully before installation and use.
2. Ohutusalane teave
HOIATUS: Nende ohutusjuhiste eiramine võib põhjustada tulekahju, elektrilöögi, varalise kahju, tõsiseid vigastusi või surma.
- Professionaalne paigaldamine: Installation of this hot water fan heater requires plumbing and electrical connections. It is strongly recommended that installation be performed by a qualified plumber and a licensed electrician in accordance with all local and national codes.
- Elektriohutus: Ensure the unit is properly grounded. Disconnect power before servicing or performing any maintenance. Do not operate with a damaged cord or plug.
- Veeohutus: Ensure all water connections are secure and leak-free. Do not operate if water leakage is detected.
- Paigutus: Ärge blokeerige õhu sisse- ega väljalaskeavasid. Hoidke seadme ümber piisav vaba ruumi, et tagada õhuvool.
- Lapsed ja lemmikloomad: Keep children and pets away from the unit during operation, as surfaces may become hot.
- Tuleohtlikud materjalid: Do not store or use flammable materials near the heater.
- Kasutusotstarve: This heater is designed for indoor use only, specifically for heating residential or commercial spaces. Do not use for drying clothes or other unintended purposes.
3. Pakendi sisu
Carefully unpack the box and ensure all items are present and undamaged. If any items are missing or damaged, contact your supplier immediately.
- Quiet-One Kickspace Fan Heater Unit (Model B628330)
- Paigaldus- ja kasutusjuhend (käesolev dokument)

Image 1: The Smith's Environmental Products Quiet-One Kickspace Fan Heater unit. This image shows the compact design of the heater, featuring a brown casing with a front grille for air output and a top grille for air intake.
4. Tehnilised andmed
The following table outlines the key specifications for the Quiet-One Kickspace Fan Heater, Model B628330:
| Funktsioon | Spetsifikatsioon |
|---|---|
| Kaubamärk | Smithi keskkonnatooted |
| Mudeli number | B628330 (KS2008) |
| Soojusväljund | 8000 BTU |
| Heat Source Type | Hot Water (from central heating system) |
| Electrical Power (Fan) | 120V |
| Erifunktsioon | Müratu töö |
| Värv | Pruun |
| Vormitegur | Cabinet / Kickspace |
| Kasutamine siseruumides/välistingimustes | Siseruumides |
| Toote mõõtmed (P x L x K) | 10.88" x 13.88" x 3.5" |
| Paigaldustüüp | Floor Mount (Kickspace) |
| Ruumi tüüp | Bedroom, Living Room, Kitchen (under cabinet) |
| Kauba kaal | 15 naela |
| Heakskiidud | UL, CSA, RTS |

Image 2: The Smith's Environmental Products Quiet-One Kickspace Fan Heater with its key dimensions labeled. The image clearly shows the depth (10.88"), width (13.88"), and height (3.5") of the unit, essential for installation planning.
5. Paigaldamine ja seadistamine
IMPORTANT: Installation must comply with all local and national electrical and plumbing codes. It is highly recommended that a qualified professional perform the installation.
5.1 Saidi valik
- Choose a location with sufficient space for the unit (refer to dimensions in Section 4) and adequate clearance for air circulation.
- Typically installed in a kickspace under cabinets, stairs, or other confined areas.
- Ensure the location allows for easy access for maintenance and servicing.
5.2 Sanitaartehnilised ühendused
- This unit connects to your existing hot water heating system.
- Connect the supply and return lines from your heating system to the heater's heat exchanger connections.
- Use appropriate fittings and sealants to ensure watertight connections.
- Bleed air from the system after filling to ensure proper water flow.
5.3 Elektriühendused
- The unit requires a 120V electrical supply to power the fan.
- Connect the heater to a dedicated, grounded electrical circuit protected by a fuse or circuit breaker of the appropriate rating.
- Follow all wiring diagrams provided with the unit (if applicable) and adhere to local electrical codes.
- Veenduge, et kõik ühendused on turvalised ja isoleeritud.
5.4 Lõplikud kontrollid
- Verify all plumbing connections are free of leaks.
- Confirm all electrical connections are secure and correctly wired.
- Ensure the unit is properly mounted and stable.
- Check that air intake and exhaust grilles are unobstructed.
6. Operatsioon
Once properly installed and connected, operating your Quiet-One Kickspace Fan Heater is straightforward.
- Toide sisse: Ensure the electrical supply to the unit is switched on.
- Termostaadi juhtimine: The heater typically operates in conjunction with your central heating system's thermostat. When the room temperature drops below the thermostat setting, the central heating system will circulate hot water to the unit, and the fan will activate to distribute the heat.
- Fan Speed (if applicable): Some models may feature a fan speed switch (e.g., Low/High). Adjust this switch to your desired airflow and noise level. Refer to any specific controls on your unit.
- Lülita välja: To turn off the heater, simply turn off the central heating system or switch off the electrical supply to the unit.
7. Hooldus
Regulaarne hooldus tagab teie kütteseadme optimaalse jõudluse ja pikaealisuse.
- Puhastamine: Periodically clean the air intake and exhaust grilles to prevent dust and debris buildup, which can restrict airflow and reduce efficiency. Use a soft brush or vacuum cleaner.
- Filter (kui on olemas): Some models may include an air filter. Check and clean or replace the filter as recommended in specific product documentation.
- Iga-aastane ülevaatus: It is advisable to have a qualified technician inspect the unit annually, especially before the heating season, to check for leaks, electrical connections, and overall operational integrity.
- Do Not Lubricate: The fan motor is typically permanently lubricated and does not require additional oiling.
8. Veaotsing
If you encounter issues with your heater, refer to the following common problems and solutions. If the problem persists, contact a qualified technician.
| Probleem | Võimalik põhjus | Lahendus |
|---|---|---|
| Soojusväljund puudub | No hot water circulating; Thermostat not calling for heat; Air in heating system; Blocked heat exchanger. | Check central heating system and thermostat settings; Bleed air from the heating system; Contact a plumber. |
| Ventilaator ei tööta | No electrical power; Fan motor failure; Thermostat not calling for heat. | Check circuit breaker/fuse; Ensure unit is plugged in; Verify thermostat setting; Contact an electrician or service technician. |
| Vähendatud õhuvool | Blocked grilles; Dirty filter (if applicable). | Clean grilles; Clean or replace filter. |
| Ebatavaline müra | Loose components; Fan obstruction; Motor bearing wear. | Inspect for loose parts; Clear any obstructions; Contact a service technician for motor issues. |
| Vee lekkimine | Loose plumbing connections; Damaged heat exchanger. | Tighten connections; Immediately shut off water supply and contact a qualified plumber. |
9. Garantii ja tugi
For warranty information, please refer to the documentation provided at the time of purchase or visit the official Smith's Environmental Products website. If you require technical assistance, replacement parts, or service, please contact Smith's Environmental Products customer support directly. Ensure you have your model number (B628330) and purchase date available when contacting support.
Kontaktandmed: Palun vaadake tootja ametlikku webUusimate kontaktandmete saamiseks külastage veebisaiti või ostudokumentatsiooni.





