Apera Instruments AI311

Apera Instruments AI311 PH60 Waterproof pH Pocket Tester Kit User Manual

Brand: Apera Instruments

Mudel: AI311

1. Sissejuhatus

The Apera Instruments PH60 Pocket pH Tester is designed for reliable and easy pH measurement in general water solutions. This includes applications such as hydroponics, horticulture, aquaculture, pools & spas, water treatment, cooling towers, environmental monitoring, beverage making, and educational settings. The meter features a replaceable pH probe (PH60-E) specifically for general water solutions. It is also compatible with three other types of pH electrodes and an ORP probe (sold separately) for specialized applications like solid samples and surface tests.

Märkus. A few drops of 3M KCL liquid (included in the kit) should be added to low ion-strength test samples (e.g., distilled water or RO water) to significantly accelerate stabilization without affecting the pH reading.

Close-up of the PH60 pH sensor bulb

Pilt: Lähivõte view of the high-quality glass pH sensor bulb, designed for accuracy and stability.

Infographic showing various applications for the PH60 pH tester

Image: Visual representation of diverse applications including hydroponics, pools, brewing, drinking water, water treatment, aquariums, and aquaculture.

2. Mis on karbis

Your Apera Instruments PH60 Waterproof pH Pocket Tester Kit includes the following items:

Apera Instruments PH60 pH Tester Kit contents laid out in its carrying case

Image: The complete PH60 pH Tester Kit, showing the meter, calibration solutions, bottles, and accessories neatly organized in its hard-shell case.

3. Seadistamine

3.1 Aku paigaldamine

The PH60 tester requires 4 AAA batteries (included). To install or replace batteries:

  1. Unscrew the battery cap at the top of the meter.
  2. Sisestage 4 AAA-patareid, jälgides õiget polaarsust (+/-).
  3. Keerake patareipesa kate kindlalt tagasi.
PH60 pH tester with battery compartment open, showing AAA batteries

Image: The top section of the PH60 pH tester with the cap removed, revealing the battery compartment for AAA batteries.

3.2 Sondi esialgne ettevalmistamine

Before first use or if the tester has not been used for a long time (over 1 month):

  1. Pull out the battery insulation slip (if present) and remove the probe cap.
  2. Rinse the probe thoroughly with pure water (preferably distilled or deionized water, RO water is acceptable). Shake off excess water.
  3. If the tester hasn't been used for a long time (over 1 month), soak the probe in the 3M KCL soaking solution (included in the kit) for 15 minutes.
  4. Proceed to calibrate the meter before testing.

Video: Apera Instruments PH60 pH Tester Quick Start Tutorial. This video demonstrates the initial preparation steps, including removing the battery insulation slip, rinsing the probe, and soaking it in KCL solution if necessary (0:13 - 0:55).

4. Kasutusjuhised

4.1 pH kalibreerimine

The PH60 tester features 1-3 point automatic calibration with auto-buffer recognition. Always calibrate pH 7.00 first. If you need to calibrate pH 4.00 or pH 10.01, do so immediately after pH 7.00 calibration. Do NOT turn the meter off between pH 7.00 and pH 4.00/10.01 calibrations.

  1. Pour pH buffer solutions (pH 4.00, pH 7.00, pH 10.01) into the corresponding calibration vials to about half volume.
  2. Loputage sond puhtas vees ja raputage liigne vesi maha.
  3. Short press the power button to turn on the tester.
  4. Dip the probe into the pH 7.00 buffer solution. Make a quick stir, then let it stand.
  5. Long press the 'CAL' button to enter calibration mode. The screen will turn green.
  6. Wait for the reading to stabilize (a smiley icon will appear on the screen), then short press 'CAL' to finish the first point calibration. The tester will return to measurement mode, and an 'M' icon will appear at the bottom left, indicating a successful first-point calibration.
  7. Without turning off the tester, rinse the probe and repeat steps 4-6 for pH 4.00 buffer solution. An 'L' icon will appear for successful 2-point calibration.
  8. Without turning off the tester, rinse the probe and repeat steps 4-6 for pH 10.01 buffer solution. An 'H' icon will appear for successful 3-point calibration.
Step-by-step guide on how to calibrate the PH60 pH tester

Image: Detailed infographic illustrating the 3-point calibration process for the PH60 pH tester.

Video: Apera Instruments PH60 pH Tester Quick Start Tutorial. This segment demonstrates the pH calibration process (0:56 - 4:26).

4.2 pH mõõtmine

To take a pH measurement:

  1. Short press the power button to turn on the tester.
  2. Loputage sond puhtas vees ja raputage liigne vesi maha.
  3. Insert the probe into your sample solution, make a quick stir, and hold still.
  4. Take the reading as the measurement when it is fully stabilized (a smiley icon appears and stays on screen).
  5. If the Auto-Hold function is turned on (in parameter setting P4), the reading will be automatically locked when it's stable for more than 10 seconds. The 'HOLD' icon will stay on. Short press the 'CAL' button to cancel Auto-Hold and continue measuring.
  6. Short press the 'MODE' button to switch to mV mode, which is for ORP testing or technical analysis (an ORP probe is needed for ORP measurements).
Hand holding the PH60 pH tester, showing a pH reading of 7.00

Image: A hand holding the PH60 pH tester, displaying a pH reading of 7.00 and a temperature of 25.0°C.

Video: Apera Instruments PH60 pH Tester Quick Start Tutorial. This segment demonstrates the pH measurement process (4:26 - 5:33).

5. Hooldus

5.1 Probe Cleaning

The accuracy of the tester depends on the cleanliness of the probe. Always thoroughly rinse off the probe before and after each measurement with pure water.

Video: Apera Instruments PH60 pH Tester Quick Start Tutorial. This segment demonstrates probe cleaning procedures (5:33 - 6:36).

5.2 Probe Storage

Proper storage is crucial for maintaining probe longevity and accuracy.

IMPORTANT: NEVER store the probe in pure water (like tap, RO, distilled, or deionized water) as they could damage the pH sensor. If this happens, immediately soak the pH probe in the 3M KCL soaking solution overnight to restore. Then re-calibrate it before using. Pure water is only for rinsing off the probe, NOT for storage.

Video: Apera Instruments PH60 pH Tester Quick Start Tutorial. This segment demonstrates proper probe storage (6:36 - 7:29).

6. Veaotsing

Siin on mõned levinumad probleemid ja nende lahendused.

7. Tehnilised andmed

FunktsioonVäärtus
Toote mõõtmed7 x 1.6 x 1.6 tolli
Kauba kaal10 untsi
Kauba mudeli numberAI311
PatareidVaja on 4 AAA patareid (kaasas)
pH täpsus±0.01 pH
pH vahemik-2.00 kuni 16.00 pH
Temperatuurivahemik32 kuni 122 °F (0 kuni 50 °C)
Automaatne väljalülitus8 minutit ilma operatsioonita

8. Garantii ja tugi

Apera Instruments is committed to providing reliable products and ongoing support to ensure you achieve the most accurate results. For warranty information, technical assistance, or any product-related inquiries, please refer to the official Apera Instruments website or contact their customer support directly. Contact details are typically provided on the product packaging or within the full user manual.

Seotud dokumendid - AI311

Preview Apera PH60 pH-testri kasutusjuhend – juhend ja spetsifikatsioonid
Apera Instruments PH60 Premium pH-testri põhjalik kasutusjuhend, mis hõlmab seadistamist, kalibreerimist, mõõtmist, tõrkeotsingut ja tehnilisi andmeid.
Preview Apera Instruments PC60 & PH20 Pocket Tester User Manuals
Comprehensive user manuals for Apera Instruments PC60 Premium Series 5-in-1 Multi-Parameter Pocket Tester and PH20 Value Series pH Tester Kit. Includes setup, calibration, measurement, troubleshooting, and specifications.
Preview Apera EC20 taskujuhtivuse tester: kasutusjuhend ja juhend
Põhjalik kasutusjuhend Apera EC20 taskujuhtivuse testeri kohta. Siit leiate teavet seadistamise, kalibreerimise, juhtivuse mõõtmise, tehniliste andmete ja garantiiteabe kohta.
Preview Apera Instruments PH20 väärtuse pH-testri komplekti kasutusjuhend
Apera Instruments PH20 pH-testri komplekti põhjalik kasutusjuhend, mis hõlmab patareide paigaldamist, klahvistiku funktsioone, kalibreerimist, mõõtmist, parameetrite seadistamist, tõrkeotsingut, tehnilisi kirjeldusi ja garantiiteavet.
Preview Apera Instruments 5052 Seawater Salinity Pocket Tester Operation Manual
Detailed operation manual for the Apera Instruments 5052 Seawater Salinity Pocket Tester, covering technical parameters, calibration, measurement procedures, important notes, and warranty information.
Preview Apera PH60-HT pH-meetri kasutusjuhend: kõrge temperatuur ja leeliselised lahused
Põhjalik kasutusjuhend Apera PH60-HT pH-meetri kohta, mis on loodud täpseks pH mõõtmiseks kõrgel temperatuuril (kuni 140 °C) ja leeliselistes lahustes. Hõlmab komplekti sisu, kasutamist, kalibreerimist, elektroodide hooldust, parameetrite seadeid, tehnilisi kirjeldusi, tõrkeotsingut ja garantiid.