QuietWarmth THERMST-D

QuietWarmth THERMST-D Non-Programmable Thermostat User Manual

For 120V or 240V Radiant Heat Systems

1. Sissejuhatus

The QuietWarmth THERMST-D Non-Programmable Thermostat is designed to provide reliable control for 120V or 240V electric radiant floor heating systems. This thermostat offers flexible temperature management, allowing you to configure it for control based on floor temperature, room temperature, or a combination of room temperature with a floor temperature limit. It features a built-in Ground Fault Circuit Interrupter (GFCI) for enhanced safety and a clear, backlit display for easy monitoring and operation. A floor sensor is included to ensure accurate temperature readings and optimal comfort.

Esiosa view of the QuietWarmth THERMST-D Non-Programmable Thermostat, showing the digital display and control buttons.

Joonis 1: Esiosa view of the THERMST-D Thermostat.

2. Ohutusalane teave

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or property damage.

  • HOIATUS: To reduce the risk of electric shock, do not connect this device to a circuit with any phase operating down more than 150 volts to ground.
  • Paigalduse peab teostama kvalifitseeritud elektrik vastavalt kohalikele ja riiklikele elektrieeskirjadele.
  • The thermostat requires connection to a dedicated 20 Amp ahel.
  • The resistive load connected to the thermostat must not exceed 15 Amps.
  • Electric radiant floor heating systems are required by the National Electrical Code to be protected by a Ground Fault Circuit Interrupter (GFCI). This thermostat has a built-in GFCI.
  • Enne termostaadi paigaldamist või hooldamist lülitage alati kaitselülitist toide välja.
Külg view of the QuietWarmth THERMST-D Thermostat showing a warning label regarding electric shock risk.

Joonis 2: Külg view of the thermostat with safety warning label.

3. Pakendi sisu

Veenduge, et pakendis on kõik esemed olemas:

  • QuietWarmth THERMST-D Non-Programmable Thermostat
  • Põrandaandur

4. Toote lõppview

4.1 Põhifunktsioonid

  • Non-Programmable operation for radiant floor heat systems.
  • Compatible with both 120V and 240V heating systems.
  • Integrated Ground Fault Circuit Interrupter (GFCI) for safety.
  • Clear, backlit LED display for easy reading.
  • Includes a floor sensor for precise temperature control.
  • Configurable for floor temperature, room temperature, or room temperature with a floor temperature limit.
  • Seven-day energy log to monitor power consumption.
  • Supports multiple QuietWarmth mats: up to 120 sq ft for 120V systems, or 240 sq ft for 240V systems.

4.2 Komponendid

The thermostat consists of a front display unit with control buttons and a back plate for electrical connections.

  • Esipaneel: Features a digital display showing time and temperature, along with 'Up', 'OK', and 'Down' buttons for navigation and setting adjustments.
  • Tagasi: Contains wiring terminals for power input (L1, L2) and load output, as well as a connection point for the floor sensor.
Tagasi view of the QuietWarmth THERMST-D Thermostat showing wiring terminals labeled L1(L), L2(N), and Load, along with a mounting screw.

Joonis 3: Tagakülg view of the thermostat with wiring terminals.

Image of the QuietWarmth floor sensor, a black cable with a small probe at the end.

Figure 4: Included floor sensor.

5. Seadistamine ja installimine

Paigaldust peaks teostama ainult kvalifitseeritud elektrik.

5.1 Paigaldamine

  • The thermostat is designed for wall mounting.
  • Veenduge, et paigalduskoht oleks otsese päikesevalguse, tuuletõmbuse või muude soojusallikate eest kaitstud, mis võivad temperatuurinäiteid mõjutada.

5.2 Juhtmestik

Before wiring, ensure power is OFF at the circuit breaker.

  1. Connect the thermostat to a dedicated 20 Amp ahel.
  2. Identify the Line (power supply) and Load (heating mat) wires.
  3. Connect the Line wires to the L1(L) and L2(N) terminals on the thermostat's back panel.
  4. Connect the Load wires from the heating mat to the 'Load' terminals on the thermostat.
  5. Tagage korralik maandus vastavalt kohalikele elektrieeskirjadele.
  6. The thermostat is dual-voltage; it can be used with either 120V or 240V heating mats, but not simultaneously. Verify your heating mat's voltage sobib toiteallikaga.

5.3 Floor Sensor Placement

The floor sensor is crucial for accurate floor temperature control.

  • Place the sensor next to the long edge of the QuietWarmth heating mat.
  • Ensure the sensor is positioned in the heated area and not near any unheated zones or external heat sources.
  • Route the sensor wire carefully to avoid damage during installation of flooring materials.
An illustration showing a golden retriever dog sleeping on a floor with radiant heat film installed underneath, indicating warmth for floating floors.

Joonis 5: näitample of radiant heat film installation under floating floors.

An illustration showing a French bulldog puppy sleeping on a floor with radiant heat film installed underneath, indicating warmth for tile and glued floors.

Joonis 6: näitample of radiant heat film installation under tile and glued floors.

6. Kasutusjuhised

6.1 Sisselülitamine

After installation, restore power at the circuit breaker. The thermostat display will illuminate.

6.2 Temperatuuri seadistamine

  • Kasutage Up ja Alla nuppe soovitud temperatuuri reguleerimiseks.
  • Vajutage nuppu OK nuppu oma valiku kinnitamiseks.

6.3 juhtimisrežiimid

The thermostat can be configured to operate in one of three control modes:

  • Floor Temperature Control: The thermostat maintains the floor at the set temperature using the floor sensor.
  • Ruumi temperatuuri reguleerimine: The thermostat maintains the room air temperature at the set point.
  • Room Temperature Control with Floor Limit: The thermostat primarily controls room air temperature but prevents the floor temperature from exceeding a specified maximum limit, protecting sensitive flooring materials.

Refer to the full installation guide for instructions on how to select and configure these control modes.

6.4 Energy Log

The thermostat features a seven-day energy log, allowing you to monitor the power consumption of your radiant heating system. Consult the detailed manual for accessing and interpreting this data.

7. Hooldus

7.1 GFCI testimine

For continued safety, the built-in GFCI should be tested monthly.

  1. Vajutage nuppu TEST button located on the bottom of the thermostat.
  2. The GFCI should trip, cutting power to the heating system and indicating a fault.
  3. Vajutage nuppu RESET button to restore power.
  4. If the GFCI does not trip or reset correctly, discontinue use and contact a qualified electrician.
Altpoolt view of the QuietWarmth THERMST-D Thermostat showing the GFCI test button and 'Test Monthly' text.

Figure 7: Bottom of the thermostat with GFCI test button.

7.2 Puhastamine

Pühkige termostaadi välispind pehme lapigaamp riie. Ärge kasutage abrasiivseid puhastusvahendeid ega lahusteid.

8. Veaotsing

If you encounter issues with your QuietWarmth THERMST-D thermostat, refer to the following common problems and solutions:

  • Ekraani/toite puudumine:
    • Check the circuit breaker for the dedicated circuit and ensure it is in the ON position.
    • Veenduge, et kõik juhtmestiku ühendused on kindlad ja õiged.
  • Küttesüsteem ei käivitu:
    • Ensure the thermostat is set to a temperature higher than the current room or floor temperature.
    • Check if the GFCI has tripped (press the RESET button if it has).
    • Confirm the correct control mode is selected (floor, room, or room with limit).
  • GFCI Trips Frequently:
    • This indicates a ground fault. Immediately turn off power at the circuit breaker.
    • Inspect the heating mat and wiring for any damage or moisture.
    • Ensure the total resistive load does not exceed 15 Amps.
    • Contact a qualified electrician for diagnosis and repair.
  • Ebatäpsed temperatuurinäidud:
    • Verify the floor sensor is correctly installed and not damaged.
    • Ensure the thermostat is not exposed to drafts, direct sunlight, or other external heat sources.

For issues not covered here, please contact QuietWarmth customer support or a qualified electrician.

9. Tehnilised andmed

SpetsifikatsioonDetail
KaubamärkVaikneSoe
Mudeli nimiQuietWarmth Non-Programmable Thermostat
Osa numberTHERMST-D
Toote mõõtmed3" P x 4" L x 6" K
Kauba kaal11.4 untsi
VärvValge
MaterjalPlastikust
Voltage120 volti, 240 volti
Maksimaalne takistuslik koormus15 Amps
ToiteallikasJuhtmega ühendatud
Kontrolleri tüüpVajutusnupp
Temperatuuri reguleerimise tüüpKäsiraamat
Kuva tüüpLED (Backlit)
ÜhenduvustehnoloogiaJuhtmega
ErifunktsioonEnergy Usage Tracking, Built-in GFCI
PaigaldustüüpSeinakinnitus
Spetsifikatsioon MetUL
UPC696087109103

10. Garantii ja tugi

10.1 Garantii teave

The QuietWarmth THERMST-D Non-Programmable Thermostat comes with a 3-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

10.2 Klienditugi

For technical assistance, troubleshooting, or warranty inquiries, please contact QuietWarmth customer support. Refer to the product packaging or the manufacturer's webpraeguse kontaktteabe saamiseks külastage veebisaiti.

Seotud dokumendid - THERMST-D

Preview QuietWarmth Tile kiirguskile paigaldusjuhend
QuietWarmth Tile soojenduskilele põhjalik paigaldusjuhend, mis kirjeldab üksikasjalikult paigaldust, elektriühendusi ja põrandakatte integreerimist plaatide ja liimitud pindade puhul. Siit saate teada, kuidas paigaldada põrandaküttesüsteem ohutult ja tõhusalt.
Preview QuietWarmth Float kiirguskile paigaldusjuhend
Põhjalik paigaldusjuhend QuietWarmth Float põrandaküttekilele, mis sisaldab üksikasjalikku planeerimist, elektripaigaldust, aluspõranda ettevalmistust, mati paigaldamist, testimist ja tõrkeotsingut mugava ja tõhusa põrandakütte tagamiseks.
Preview Azel D-508F Digital Radiant Floor Heating Thermostat Instruction Manual
Comprehensive instruction manual for the Azel Technologies D-508F digital non-programmable universal radiant floor heating thermostat. Learn about installation, operation modes (A, F, AF), temperature settings, wiring, error codes, and specifications.
Preview MP Global Products Radiant Heat Filmi piiratud garantii ja registreerimine
See dokument kirjeldab MP Global Productsi kiirgusküttekilele ujuv- või plaatpõrandate all kasutatava piiratud garantiid. See kirjeldab garantiiaega, garantii kehtivust, erandeid ja nõude esitamise protsessi. See sisaldab ka süsteemi kontroll-lehte ja garantii registreerimisvormi, mida majaomanikud saavad pärast paigaldamist täita.
Preview THERMAEGH nutika termostaadi kasutusjuhend ja Google Home'i integreerimise juhend | MP Global
MP Global THERMAEGH nutika termostaadi põhjalik kasutusjuhend, mis hõlmab paigaldamist, kasutamist, seadistamist, tõrkeotsingut ja integreerimist Google Home'iga. Sisaldab garantiiteavet.