1. Sissejuhatus
This manual provides instructions for the safe installation, operation, and maintenance of the Leviton 8200-LW 15-Amp, 125-Volt, Hospital Grade Duplex Receptacle. Please read these instructions thoroughly before beginning installation and retain them for future reference.
Pilt 1: esikülg view of the Leviton 8200-LW Hospital Grade Duplex Receptacle in White.
2. Oluline ohutusteave
HOIATUS: TULEKAHJU, LÕUKI VÕI SURMA VÄLTIMISEKS; LÜLITA VÄLJA VÕI VÕI KAITSME TOIDE JA TESTAGE ENNE JUHTMETE ALUSTAMIST, KAS TOIDE ON VÄLJAS!
- Installation must be performed by a qualified electrician in accordance with all national and local electrical codes and regulations.
- Enne elektrijuhtmestikuga töötamist ühendage alati toitejuhe lahti peamise teeninduspaneeli juurest.
- Kasutage ainult vask- või vasega kaetud traati. Ärge kasutage selle seadmega alumiiniumtraati.
- Veenduge, et kõik juhtmeühendused on kindlad ja korralikult isoleeritud.
- See seade on mõeldud kasutamiseks ainult siseruumides.
- Ärge ületage seadme määratud elektrilisi nimivõimsusi.
3. Pakendi sisu
The package for the Leviton 8200-LW Duplex Receptacle typically includes:
- One (1) Leviton 8200-LW 15-Amp, 125-Volt, Hospital Grade Duplex Receptacle (White)
4. Toote spetsifikatsioonid
| Mudeli number: | 8200-LW |
| Amptõus: | 15 Amps |
| Voltage: | 125 volti |
| Konfiguratsioon: | 5-15R |
| Juhtmed: | 3-Wire, Self-Grounding (Back and Side Wiring) |
| Poolakad: | 2-Pole |
| Materjal: | Nylon (Body/Face) |
| Värv: | Valge |
| Heakskiidud: | UL, CSA C22.2, NOM 057 |
| Tüüp: | Heavy Duty, Hospital Grade |
5. Seadistamine ja installimine
Vajalikud tööriistad: Screwdriver (Phillips and/or Flathead), Wire Strippers, Electrical Tape, Voltage Tester.
- Lülitage toide välja: Locate the circuit breaker or fuse that controls the outlet you are replacing or installing. Turn off the power and verify it is off using a voltage testija.
- Eemaldage vana pistikupesa (kui see on olemas): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box.
- Juhtmete lahtiühendamine: Note the position of each wire before disconnecting. Typically:
- Roheline või paljas vasktraat: Maandusjuhe.
- Valge traat: Neutraalne juhe.
- Black or Red Wire: Hot (live) wire.
- Valmistage juhtmed ette: If necessary, strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the wires. Ensure the wire ends are clean and straight.
- Connect Wires to New Receptacle: The Leviton 8200-LW supports both back and side wiring.
- Maandusjuhe (roheline või paljas vask): Connect to the green hexagonal ground screw.
- Neutraaljuhe (valge): Ühendage hõbedaste klemmikruvidega.
- Hot Wire (Black or Red): Ühendage messingist klemmkruvidega.
For Side Wiring: Loop the wire clockwise around the screw terminal and tighten securely. Ensure no bare wire is exposed outside the terminal.
For Back Wiring: Insert the stripped wire end into the appropriate hole on the back of the receptacle and tighten the corresponding screw on the side. The V-shaped, serrated back-wiring clamps ensure superior contact.
- Turvaline mahuti: Carefully fold the wires into the electrical box. Insert the new receptacle into the box and secure it with the mounting screws.
- Paigaldage seinaplaat: Attach the wall plate over the receptacle.
- Toite taastamine: Lülitage kaitselüliti või kaitsme abil toide uuesti sisse.
- Test: Test the receptacle with a known working device.
6. Kasutusjuhised
The Leviton 8200-LW Duplex Receptacle functions as a standard electrical outlet. Once properly installed and powered, simply insert the plug of your electrical device into one of the two available outlets. Ensure the plug is fully inserted for a secure connection.
7. Hooldus
- Puhastamine: Pistikupesa puhastamiseks veenduge, et kaitselüliti on välja lülitatud. Pühkige pind pehme lapiga.amp riie. Ärge kasutage abrasiivseid puhastusvahendeid ega lahusteid.
- Ülevaatus: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, disconnect power and have the device inspected or replaced by a qualified electrician.
- "Green Dot" Marking: This hospital-grade receptacle features a permanent "Green Dot" marking on its face, indicating its compliance with hospital-grade standards for enhanced durability and reliability.
8. Veaotsing
| Probleem | Võimalik põhjus | Lahendus |
|---|---|---|
| Pistikus pole voolu. | Kaitselüliti on rakendunud või kaitse on läbi põlenud. Juhtmestik on lahti. | Check and reset the circuit breaker or replace the fuse. Turn off power and check all wire connections for tightness. |
| Pistik tundub pistikupesas lahti. | Worn receptacle contacts (unlikely for new hospital-grade). Incorrect plug type. | Ensure the plug is fully inserted. If the issue persists with multiple devices, consult a qualified electrician for inspection. |
| Pistikupesa on puudutades kuum. | Overload on the circuit. Loose connection. Faulty device. | Immediately disconnect power. Reduce the load on the circuit. Have a qualified electrician inspect the wiring and device. |
9. Garantii ja tugi
Leviton products are manufactured to the highest quality standards. For specific warranty information and customer support, please refer to the documentation included with your purchase or visit the official Leviton websait. Hoidke ostutšekk ostutõendina alles.
Levitoni klienditugi:
- Külasta Levitoni tuge Websaidile
- Refer to the contact information provided on the product packaging.