1. Sissejuhatus

The Intermatic EI500WC is a 7-day single-pole digital time switch designed for automated control of lights, fans, pumps, and other medium-duty loads. It offers up to 7 ON and 7 OFF operations per week, providing flexibility for energy savings, security, and convenience. This timer is compatible with incandescent, fluorescent, CFL, and LED lighting.

This manual provides detailed instructions for the safe installation, setup, programming, and maintenance of your EI500WC digital time switch.

Intermatic EI500WC Digital Time Switch installed in a wall plate

Figure 1: Intermatic EI500WC Digital Time Switch installed in a standard wall plate.

2. Ohutusmeetmed

Please read and understand all instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or serious injury.

3. Pakendi sisu

4. Toote lõppview

The EI500WC features a clear digital display and intuitive buttons for programming. The main ON and OFF buttons are visible on the front, while programming buttons are located behind a hinged cover.

Intermatic EI500WC Digital Time Switch with programming buttons exposed

Joonis 2: Esiosa view of the EI500WC with the programming button cover open, showing CLK, DAY, PROG, RESET, HOUR, MIN, and MODE buttons.

5. Paigaldusjuhised

5.1. Vajalikud tööriistad

5.2. Juhtmete ühendamise juhised

  1. Lülitage toide välja: Leidke vahetatavat lülitit juhtiv kaitselüliti või sulavkaitse ja lülitage see VÄLJA. Veenduge, et toide on välja lülitatud, kasutades volüümiandurit.tage testija.
  2. Eemaldage vana lüliti: Carefully remove the existing wall plate and switch from the electrical box.
  3. Tuvastage juhtmed: The EI500WC requires a neutral wire. Identify the LINE (hot), LOAD, NEUTRAL, and GROUND wires in your electrical box. If a neutral wire is not present, consult a qualified electrician.
  4. Ühendage juhtmed: Use the provided wire nuts to connect the EI500WC wires to your household wiring as shown in the diagram below.
    • Black wire (LINE): Ühendage kaitselülitist tuleva kuumajuhtmega.
    • Red wire (LOAD): Connect to the wire going to the light fixture or appliance.
    • White wire (NEUTRAL): Connect to the neutral wire (typically white) in the electrical box.
    • Green wire (GROUND): Ühendage elektrikarbi palja vask- või rohelise maandusjuhtmega.
Wiring diagram for Intermatic EI500WC Digital Time Switch

Figure 3: Wiring diagram for the EI500WC, showing connections for LINE (Black), LOAD (Red), NEUTRAL (White), and GROUND (Green).

5.3. Paigaldamine

  1. Carefully push the wired timer into the electrical box, ensuring wires are not pinched.
  2. Secure the timer to the electrical box using the mounting screws.
  3. Attach the wall plate (not included) over the timer.
  4. Taasta võimsus: Lülitage kaitselülitist toide uuesti sisse.

6. Algseadistus

Esmakordsel sisselülitamisel või pärast toite väljalülitamisttage, the display may show '12:00 AM' and 'MO'. The internal battery maintains settings during brief power interruptions.

6.1. Praeguse kellaaja ja päeva määramine

  1. Open the hinged cover to access the programming buttons (refer to Figure 2).
  2. Vajutage nuppu CLK nuppu. Ajanäidik hakkab vilkuma.
  3. Vajutage nuppu TUND button to set the current hour. Observe the AM/PM indicator.
  4. Vajutage nuppu MIN nuppu praeguse minuti määramiseks.
  5. Vajutage nuppu PÄEV button to set the current day of the week (MO, TU, WE, TH, FR, SA, SU).
  6. Vajutage CLK again to save the settings and exit time setting mode.

7. Kasutamine ja programmeerimine

The EI500WC allows for up to 7 ON and 7 OFF programming events per week. Each event can be set for a specific day or combination of days.

7.1. Sisse-/väljalülitusprogrammide seadistamine

  1. Avage hingedega kaas.
  2. Vajutage nuppu PROG nuppu. Ekraanile kuvatakse „1 ON“ ja aeg vilgub.
  3. Vajutage TUND ja MIN to set the desired ON time for program 1.
  4. Vajutage PÄEV to select the day(s) for this program. Options include individual days, weekdays (MO TU WE TH FR), weekends (SA SU), or all days (MO TU WE TH FR SA SU).
  5. Vajutage PROG uuesti. Ekraanile kuvatakse „1 OFF” ja aeg vilgub.
  6. Vajutage TUND ja MIN programmi 1 soovitud väljalülitusaja määramiseks.
  7. Vajutage PÄEV to select the day(s) for this OFF program (should match the ON program days).
  8. Repeat steps 2-7 for additional ON/OFF programs (up to 7 pairs). To skip a program, press PROG repeatedly until you reach the desired program number or exit programming mode.
  9. Vajutage CLK to exit programming mode and return to normal operation.

7.2. Juhuslik režiim

The random mode feature varies the ON/OFF schedule by a few minutes, providing a 'lived-in' appearance for enhanced security.

7.3. Käsitsi alistamine

You can manually turn the connected load ON or OFF at any time without affecting the programmed schedule.

8. Hooldus

8.1. Aku teave

The EI500WC includes an internal battery that provides backup power to maintain time and program settings during power outages. This battery is typically long-lasting and not user-replaceable. If the display is blank or settings are lost frequently after power interruptions, the unit may need replacement.

8.2. Puhastamine

Puhastage taimeri pinda pehme lapigaamp riie. Ärge kasutage abrasiivseid puhastusvahendeid ega lahusteid.

9. Veaotsing

10. Tehnilised andmed

FunktsioonSpetsifikatsioon
Mudeli numberEI500WC
Voltage125 VAC, 60 Hz
Maksimaalne koormus15 Amps (1875 Watts) Resistive, 1000 Watts Tungsten
Mootori koormus1 / 4 HP
Programmide arvUp to 7 ON/OFF events per week
Lüliti tüüpSingle-Pole (1-way)
PaigaldustüüpDecorator Wall Plate/Standard Wall Box
Mõõdud (K x L x S)2.75" x 1.75" x 1.36"
VärvValge
SertifikaadidUL nimekirjas

11. Garantii teave

Intermatic warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. This warranty covers replacement of the unit only and does not include labor costs associated with removal or reinstallation.

This warranty does not apply to defects resulting from improper installation, misuse, abuse, accident, or unauthorized modifications. For warranty service, please contact Intermatic customer support.

12. Klienditugi

If you have any questions regarding the installation, operation, or troubleshooting of your Intermatic EI500WC Digital Time Switch, please refer to the Intermatic website or contact their customer support directly. Always have your model number (EI500WC) available when contacting support.

Seotud dokumendid - EI500WC

Preview Intermatic HB880R Outdoor 7-Day Digital Timer: User Manual & Instructions
Comprehensive operating and user instructions for the Intermatic HB880R Outdoor 7-Day Digital Timer. Learn how to set schedules, manage settings, and troubleshoot this programmable time switch.
Preview Intermatic HB880R digitaalne taimer välistingimustes kasutamiseks: kasutusjuhend
Põhjalik juhend Intermatic HB880R 7-päevase digitaalse taimeri kohta. Siit saate teada, kuidas seadistada kella, programmeerida sündmusi, lubada akut ja lahendada levinud probleeme optimaalse välisvalgustuse juhtimiseks.
Preview Intermatic HB880R digitaalne taimer välistingimustes kasutamiseks: kasutusjuhend
Detailed operating and user instructions for the Intermatic HB880R Outdoor 7-Day Digital Timer. This guide covers setup, programming of calendar, clock, astronomic settings, and events, daily operation modes, troubleshooting, and warranty information.
Preview Intermatic elektroonilise 7-päevase veesoojendi taimeri lülitid EH10 EH40 kasutusjuhend
Põhjalik kasutusjuhend Intermatic EH10 ja EH40 elektrooniliste 7-päevaste veesoojendite taimerlülitite kohta. Hõlmab paigaldus-, programmeerimis-, spetsifikatsiooni-, ohutus- ja garantiiteavet.
Preview Intermatic EJ341C/EJ343C valgusaja taimeri paigaldus- ja programmeerimisjuhend
Põhjalik juhend Intermatic EJ341C (ühepooluselise) ja EJ343C (kolmesuunalise) elektrooniliste valgustaimerite paigaldamiseks ja programmeerimiseks. Õpi seadistamist, kasutamist ja tõrkeotsingut.
Preview Intermatic EI500 Series Electronic 7-Day In-Wall Time Switch Installation and User Instructions
Comprehensive installation and user guide for the Intermatic EI500 Series Electronic 7-Day In-Wall Time Switch. Learn how to install, set the clock, program events, and operate your time switch for energy savings and convenience.