APC AP7921

APC AP7921 Switched Rack PDU User Manual

Mudel: AP7921

1. Sissejuhatus ja lõppview

The APC AP7921 is a Switched Rack Power Distribution Unit (PDU) designed for efficient power management in rack environments. This 1U horizontal mounting PDU provides eight (8) C13 output receptacles and accepts a 208V-230V input via an IEC-320 C20 connector, supporting a 16A single-phase load. It offers advanced features such as remote individual outlet control, local current monitoring, and remote management capabilities, making it suitable for critical IT infrastructure.

APC AP7921 Switched Rack PDU front view with 8 C13 outlets and display

Joonis 1.1: Esiosa view of the APC AP7921 Switched Rack PDU, showing the eight C13 output receptacles and the local current monitoring display.

Peamised omadused:

2. Ohutusalane teave

Read and understand all instructions before installing or operating this equipment. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Pakendi sisu

Verify that all components are present upon unpacking. If any items are missing or damaged, contact your vendor or APC support.

4. Seadistamine ja installimine

4.1 Riiuli paigaldamine

  1. Identify a 1U (1.75 inches) space in your standard 19-inch server rack.
  2. Attach the provided mounting brackets to the sides of the PDU using the included screws.
  3. Secure the PDU into the rack using appropriate rack screws, ensuring it is firmly seated.

4.2 Toiteühendus

  1. Connect the IEC-320 C20 input connector of the PDU to a compatible 208V-230V, 16A power source. Ensure the power source is properly grounded and capable of supplying the required current.
  2. Connect your IT equipment's power cords to the eight (8) C13 output receptacles on the PDU. Distribute the load evenly across the outlets if possible.

5. Operatsioon

5.1 Sisselülitamine

Once the PDU is connected to a power source, it will power on automatically. The local current monitoring display will illuminate, showing the total current draw.

5.2 Local Current Monitoring

The integrated display on the front panel provides real-time information on the total current being drawn by all connected devices. This helps in preventing overloads and managing power capacity.

5.3 Remote Individual Outlet Control

The AP7921 allows for remote control of each individual C13 outlet. This feature enables users to power cycle, turn on, or turn off connected equipment remotely, which is beneficial for troubleshooting or managing power to specific devices without physical access.

5.4 Power Delays

The PDU supports configurable power-on and power-off delays for its outlets. This feature helps in sequencing the startup of equipment to prevent inrush current overloads and manage system dependencies.

6. Konfiguratsioon

The AP7921 PDU offers various configuration options through its network interface for remote management.

6.1 Võrgujuurdepääs

Connect the PDU to your network using an Ethernet cable. Access the PDU's web interface via its assigned IP address to configure settings, monitor status, and control outlets. Refer to the network configuration guide for initial setup.

6.2 Häire läved

Configure alarm thresholds for current draw. The PDU can send alerts via email or SNMP traps if the current exceeds or falls below specified limits, helping to prevent overloads or identify power issues.

6.3 Püsivara värskendused

The PDU's firmware is flash upgradeable. Regularly check the APC website for the latest firmware versions to ensure optimal performance and access to new features. Follow the provided instructions for firmware upgrade procedures.

7. Hooldus

7.1 Puhastamine

Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure the PDU is disconnected from the power source before cleaning.

7.2 Keskkonnakaalutlused

Ensure the PDU operates within its specified temperature and humidity ranges. Maintain proper airflow around the unit to prevent overheating.

8. Veaotsing

8.1 No Power to Outlets

8.2 Overload Indication

8.3 Kaugjuurdepääsu probleemid

9. Tehnilised andmed

FunktsioonSpetsifikatsioon
Mudeli numberAP7921
Sisend Voltage208V-230V
Sisendvool16A
SisendiühendusIEC-320 C20
Väljundmahutid8 x IEC-320 C13
Vormitegur1U Horizontal Rack-Mountable
Toote mõõtmed (K x L x S)2.7 x 18.5 x 13.5 tolli (umbes)
Kauba kaal1.54 naela
Juhtme pikkus7.8 tolli
ErifunktsioonMountable, Switched Outlets, Remote Management
TootjaAPC

10. Garantii ja tugi

For warranty information, technical support, or service inquiries, please refer to the official APC website or contact your local APC representative. Ensure you have your product model number (AP7921) and serial number available when contacting support.

Interneti-ressursid: Külastage www.apc.com for product documentation, software downloads, and support contact information.

Seotud dokumendid - AP7921

Preview APC kommuteeritava rack-toitejaotusseadme paigaldusjuhend
APC lülitusega rack-toitejaotusseadmete (PDU-de) paigaldus- ja kasutusjuhend, mis hõlmab funktsioone, paigaldamist, konfigureerimist, juurdepääsu, garantiid ja tuge.
Preview APC Easy PDU Metered-by-Outlet Rack Power Distribution Unit Installation Guide
Installation guide for APC Easy PDU Metered-by-Outlet Rack Power Distribution Units (EPDU2116MBO, EPDU2132MBO, EPDU2216MBO, EPDU2232MBO), covering safety, installation, display interface, and specifications.
Preview APC SMT2200/SMT3000 PDU vahetamise paigaldusjuhend | Schneider Electric
See juhend annab juhised APC SMT2200 ja SMT3000 UPS-süsteemide valikulise asendus-PDU-paneeli paigaldamiseks. See sisaldab olulisi ohutusjuhiseid, toote käsitsemise juhiseid ja samm-sammult paigaldusprotseduure.
Preview APC NetShelter Rack PDU täiustatud ja riiulisüsteemide tootejuhend
Põhjalik juhend APC NetShelter Rack PDU-de kohta, sh täiustatud 4-ühes pistikupesaga mudelid, põhilised, mõõdetud, lülitatavad ja pistikupesapõhiselt mõõdetud valikud andmekeskuse toitehalduseks. Funktsioonide spetsifikatsioonid, lisatarvikud ja riiulisüsteemi lahendused.
Preview APC Rack toitejaotusseadme paigaldusjuhend
APC riiulitüüpi toitejaotusseadmete (PDU-de) paigaldusjuhised, sh ohutusnõuded, paigaldusprotseduurid ja teave kuvari liidese kohta.
Preview APC NetShelter AR1000, AR1001, AR1100 paigaldus- ja kasutusjuhend
See käsiraamat annab üksikasjalikud juhised American Power Conversion (APC) NetShelteri riiulikorpuste, sh mudelite AR1000, AR1001 ja AR1100 paigaldamiseks, seadistamiseks ja hooldamiseks. See hõlmab toote inventuuri, hoiatusi, konfigureerimist, nivelleerimist, stabiliseerimist ja garantiiteavet.